HMI Modbus APK
Version 2.23 - net.sagram.hmi_modbussagram,hmi_modbus,tools,modbus
Provides communication protocols Modbus TCP/IP and RTU (TCP and Bluetooth)
APP Information
Download Version | 2.23 (123) |
Apk Size | 13.29 MB |
App Developer | Sagram.net |
Malware Check | TRUSTED |
Install on Android | 4.4.x and up |
App Package | net.sagram.hmi_modbus.apk |
MD5 | db3af8858da05adef1f73643579270e1 |
Rate | 5 |
Table of Contents
Download HMI Modbus 2.23 APK
App Description
HMI Modbus is sagram,hmi_modbus,tools,modbus, content rating is Everyone (PEGI-3). This app is rated 5 by 1 users who are using this app. To know more about the company/developer, visit Sagram.net website who developed it. net.sagram.hmi_modbus.apk apps can be downloaded and installed on Android 4.4.x and higher Android devices. The Latest Version of 2.23 Available for download. Download the app using your favorite browser and click Install to install the application. Please note that we provide both basic and pure APK files and faster download speeds than APK Mirror. This app APK has been downloaded 180+ times on store. You can also download net.sagram.hmi_modbus APK and run it with the popular Android Emulators.
This software can be used as replacement for HMI operator panel. Some functions of Scada-systems such as reading and writing different data types are provided. Modbus TCP/IP protocol is supported. In order to use Modbus RTU/ASCII additional Modbus converter (for example tgw-715) is necessary. If you need only viewer: https://play.google.com/store/apps/details?id=net.sagram.hmi_modbus_viewer. Manual: https://drive.google.com/drive/folders/0B_ogMSvuFCPAcUgyZURYaDF1ZTg?usp=sharing Also implemented communication through Bluetooth (Modbus RTU), can be used for communication via Bluetooth shield for Arduino and other devices. Viewing requests and responses in Hex format in the log. Program interface is based on Drag and Drop principle. Long tap on element in editing mode is used to move that element within workspace. Most external HMI are using port no. 8000, PLC port usually set to 502. Read/write functions currently supports Int 16, Int 32, Float, Float swapped, Boolean data types. Software was tested on HMI panel Weintek MT6070iH, Delta DVP20EX2 PLC, Siemens s7-1200 PLC
App ChangeLog
- Fixed permissions for bluetooth and usb devices (Android above 12). Bugs fixed
App Screens
d7c42613d5bb2d0b17d1e6e885cab85fa2a3822e.apkApk scan results
Apk Scaned By TotalVirus Antivirus,net.sagram.hmi_modbus.apk Was Pure And Safe. Scan Stats:malicious:0|suspicious:0|undetected:67|harmless:0|timeout:0|confirmed-timeout:0|failure:0|type-unsupported:9| Name:d7c42613d5bb2d0b17d1e6e885cab85fa2a3822e.apk SHA-1:d7c42613d5bb2d0b17d1e6e885cab85fa2a3822e SHA-256:5966e14216d4f8c0efec10f706bc3b23262509451338b32f94a1ceb4e7ed6b0a SSDEEP:393216:fTaWuaBlvwyWVx1uz1capYBuSPSqhlaVSGCYRX8:OY6BuXeuSPSqhsVOYe File type:Android Magic:Zip archive data, at least v0.0 to extract, compression method=deflate File size:13935508 Uncompressed Size:35727118 Contained Files :1616 Contained Files By Type:dex:3,bin:4,obj:1,xml:439,5g:1,txt:139,png:278,
Zachariah Jaime
Needed a basic communication app to test Modbus features on a PLC, this far exceeded my expectations and was extremely easy to set up and use.
Michael
Amazing app, in no time you can setup a nice panel! Bunch of thanks to the développer, I am more than happy to donate in order to remove the small advert banner at the bottom of the screen.
Divyaraj Jhala
Honestly I didn't expect this to work at all but It's made so easy to use, I created my project in 5 minutes and on the first trial I got the perfect result. I used Schneider PLC with TCP/IP to read/write data
Christian Rank
It works great. But the ModBus-Modul i use, needs "Write Multiple Registers (0x10)".Is it possible to program this in one of the next versions? With 0x03 and int16 it doesn't work with the module "simple EVSE WB". Reading works fine.
Tom G
Connects to mb server but the buttons in the app don't work.. so I couldn't do anything with it
Ondra Šebesta
Great app, but doesn't work with FT4232H.
Mariza Camilot
tested on industrial field simulation, i'll use to control power plants. Good software, congratulations to developed guy. puta programa massa xomano (portuguese congratulations mode on)
Simon Gibson
not clear about addressing 32bit real numbers and whether or not the 40001 offset is added by default.
Virakyuth Luong
Use with my project is the same what I want. Run the same with my BMS. ☺️
John Brown
Great app for me